BJZWZ - MERCURIC OXIDE CELL 303654A
- MSDS: BJZWZ
- Manufacturer: DURACELL INC TECHNICAL SALES AND MARKETING GROUP
- Product Name: MERCURIC OXIDE CELL 303654A
- National Stock Number: 6135-00-838-0706
Product Identification
Product ID:MERCURIC OXIDE CELL 303654A
MSDS Date:03/04/1997
FSC:6135
NIIN:00-838-0706
MSDS Number: BJZWZ
Responsible Party
BETHEL, CT 06801
US
Emergency Phone: 203-796-4682/4575
Info Phone: 800-243-9540/FAX 203-796-4518
Preparer: EH & S DEPARTMENT
Cage: 90303
Contractor
Telephone: 203-796-4000
Cage: 0GV58
Ingredients
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 9%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MERCURIC OXIDE (SARA 302/313) (CERCLA)
CAS: 21908-53-2
RTECS: OW8750000
Fraction By Weight: 35-45%
OSHA PEL 0.1 MG (HG)/M3; Z-2
ACGIH TLV: S,0.025 MG(HG)/M3;96
MERCURY (SARA 313) (CERCLA)
CAS: 7439-97-6
RTECS: OV4550000
Fraction By Weight: < 1%
OSHA PEL C, 0.1 MG/M3; Z-2
ACGIH TLV: S,0.025 MG/M3; A4;96
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ZINC (SARA 313) (CERCLA)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 15%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MANGANESE OXIDE
CAS: 1317-35-7
RTECS: OP0895000
Fraction By Weight: 6%
OSHA PEL C 5 MG(MN)/M3
ACGIH TLV: 5 MG (MN)/M3; 9596
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE AND CHRONIC- RISK OF EXPOSURE
OCCURS ONLY IF CELL IS MECHANICALLY, PHYSICALLY OR ELECTRICALLY
ABUSED. KOH IS CAUSTIC AND MAY CAUSE SKIN BURNS, SEVERE EYE INJURY.
AT ELEVATED TEMPERATURES, MERCUR Y VAPORS MAY BE GENERATED WHICH
CAN CAUSE MERCURY INTOXICATION.
Explanation of Carcinogenicity:MFR LISTED NO FURTHER INFORMATION ABOUT
THE CARCINOGENICITY OF THIS MATERIAL.
Effects of Overexposure:SKIN & EYE CONTACT WITH KOH MAY CAUSE CHEMICAL
BURNS. AT ELEVATED TEMPERATURES, MERCURY VAPOR MAY BE GENERATED
WHICH SHOULD NOT BE INHALED.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
GENERALLY AGGRAVATE ANY MEDICAL CONDITION.
First Aid
First Aid:IF LEAKAGE FROM CELL COMES INTO CONTACT WITH THE SKIN, FLUSH
IMMEDIATELY WITH WATER. FOR EYE CONTACT, FLUSH EYES IMMEDIATELY
WITH COPIOUS AMOUNTS OF WATER FOR 15 MINUTES AND SEE A PHYSICIAN AT
ONCE. F OR INHALATION OF HG VAPORS, REMOVE TO FRESH AIR. IF
SWALLOWED, CONSULT PHYSICIAN AT ONCE. FOR INFO, CALL NATIONAL
POISON CONTROL CENTER, 202-625-3333.
Fire Fighting
Flash Point:NONE
Extinguishing Media:MFR: "N/A" HMIS: USE MEDIA APPROPRIATE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING FIRE WHERE THESE CELLS ARE
INVOLVED.
Unusual Fire/Explosion Hazard:CELLS MAY RELEASE TOXIC MERCURY VAPOR
WHEN THE INTEGRITY OF THE CELL IS BROKEN.
Accidental Release
Spill Release Procedures:HMIS:BATTERY AND CELL CASES WILL NORMALLY
CONTAIN MATERIALS OF CONCERN. USE INDUSTRIAL ABSORBENT TO COLLECT
LIQUID POTASSIUM HYDROXIDE. MFR:AVOID SKIN AND EYE CONTACT. DO NOT
INHALE VAPORS.
Neutralizing Agent:WEAK ACID FOR POTASSIUM HYDROXIDE
Handling
Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. AVOID
BREAKING, CRUSHING OR OTHERWISE DESTROYING THE PHYSICAL INTEGRITY
OF BATTERY. OBSERVE THE CORRECT POLARITY.
Other Precautions:DO NOT INCINERATE. DO NOT TOUCH BROKEN OR LEAKING
BATTERIES. AVOID MECHANICAL OR ELECTRICAL ABUSE. DO NOT ATTEMPT TO
RECHARGE. AVOID SHORT CIRCUITS. DO NOT CARRY BATTERIES LOOSE IN
POCKET OR BAG. KEEP BATTERIES AWAY FROM SMALL CHILDREN.
Exposure Controls
Respiratory Protection:SELF CONTAINED BREATHING APPARATUS IF CELLS ARE
ENVOLVED IN A FIRE.
Ventilation:WHEN CELLS ARE INVOLVED IN A FIRE USE AS MUCH VENTILATION
AS POSSIBLE.
Protective Gloves:NEOPRENE, LATEX-NITRILE, OR RUBBER
Eye Protection:SAFETY GLASSES WHEN HANDLING LEAKERS
Other Protective Equipment:NONE
Work Hygienic Practices:MFR: ?. HMIS:USE GOOD CHEMICAL HYGIENE
PRACTICE. AVOID UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING
OR DRINKING.
Supplemental Safety and Health
REPLACE ALL BATTERIES IN EQUIPMENT AT THE SAME TIME. DO NOT MIX BATTERY
SYSTEMS (I.E. MERCURY, ALKALINE, ZINC-CARBON) IN THE SAME
EQUIPMENT. INSTALL CELLS ACCORDING TO EQUIPMENT INSTRUCTIONS.
Chemical Properties
HCC:Z7
NRC/State Lic Num:NONE
Appearance and Odor:DRY CELL TYPE BATTERY 01.060 IN O.D. X 3.000 IN
LONG; 14 VOLTS.
Stability
Stability Indicator/Materials to Avoid:YES
NO INFORMATION GIVEN ON MSDS BY MFR.
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, PUNCTURE OR
RECHARGE
Hazardous Decomposition Products:WHEN HEATED, CELLS MAY EMIT TOXIC
MERCURY VAPORS AND CAUSTIC POTASSIUM HYDROXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS. NO SPECIAL PRECAUTIONS ARE NECESSARY FOR SMALL
QUANTITIES OF MERCURY BATTERYS. FOR DISPOSAL OF LARGE QUANTITIES OF
BATTERYS, CONSULT LOCAL ENVIRONMENT AL AGENCYS OR DURACELL. DO NOT
INCINERATE!
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.